Aircraft Hangar

1122 Mivvik Street, Iqaluit (Nunavut)

Fall Protection

Scope of work

Turnkey design, supply, installation and testing of state-of-the-art overhead fall protection systems for maintenance on various aircraft in the Iqaluit hangar facility.

Description of system

The 3M engineered 8 mm stainless steel cables complete with energy absorbers, tensioners, rolling travellers, and support brackets were installed on our custom adjustable supports. Innovative Access performed the energy analysis and fall clearance calculations for the system, structural validation of the supporting structure and reinforcements via cables to distribute fall arrest loads. Along with engineered operational drawings, our team provided training to the maintenance staff, end users, log book, and remains involved for annual maintenance, engineer inspections and training as required.